Model VFP CA 1
Capacity 1 Kgs.
IS No. IS 15683:2018 — verify the current BIS licence and marking for the exact supplied model
Fire Rating 8B
Operating Temperature -20° C TO +55° C
Min. Jet Length (in mtrs) 2 Mtrs.
Discharge Percentage Min. 95%
Discharge Time Min. 8 Seconds
Charge Pressure 15 Kgf / cm²
Test Pressure 250 Kgf / cm²
Operating Valves Squeeze Grip Type
Extinguisher Media HFC 236
Expellant Dry Nitrogen
Anti Corrosive Treatment Phosphating (7 Tanks)
Painting Epoxy Polyester Powder Coating
Tare Weight ( Approximate) 1.2 kg
Full Weight ( Approximate) 2.2 kg
Quick answer

What is the Vintex VFP CA 1 fire extinguisher?

The Vintex VFP CA 1 is listed as a 1 kg portable clean agent fire extinguisher using HFC 236 medium with an 8B fire rating. It should only be selected for hazards covered by the exact current label, datasheet and approvals. Additional electrical or fire-class suitability must be verified rather than assumed.

Product overview

Compact clean agent extinguisher for a model-specific assessed risk

The visible product data lists a 1 kg capacity, squeeze-grip operation, dry-nitrogen expellant, approximately 8-second discharge time and HFC 236 extinguishing medium. Its compact format can support selected portable-fire requirements where the rating is appropriate.

A clean agent category name does not establish suitability for every electronic, vehicle or server-room hazard. Confirm the actual fire load, enclosure, ventilation, agent compatibility, operating conditions and local approval requirements.

01

1 kg capacity

Compact portable format; verify that the listed rating covers the assessed hazard.

02

Model VFP CA 1

Use this model reference when requesting current documents and quotation details.

03

HFC 236 medium

Request the exact agent datasheet, safety data sheet and regulatory information.

04

Listed 8B rating

Do not extend this rating to other fire classes without current test and approval evidence.

Standards and verification

Confirm the rating, licence and exact agent documentation

BIS lists IS 15683:2018, Portable Fire Extinguishers — Performance and Construction — Specification. If an ISI-marked unit is required, verify the current BIS licence, scope, model marking, rating and test documents for VFP CA 1. Also request the HFC 236 safety data sheet and applicable environmental or regulatory information.

Manufacturer, supplier and dealer enquiries

1 kg clean agent extinguisher supply from Mumbai across India

Vintex accepts project and bulk enquiries from facilities, contractors, consultants, system integrators and procurement teams. Share the model, exact agent and rating requirement, quantity, destination and approval conditions.

Supplier and prospective dealer enquiries are reviewed against territory, demand, product mix, commercial terms and service capability. Enquiry coverage does not mean an authorised dealer or stocked inventory already exists in every city.

01

Manufacturer enquiries

Request current technical data, agent information, certification and project quantities.

02

Supplier enquiries

Submit destination, quantity, specifications and delivery requirement for supply support.

03

Dealer enquiries

Share your company profile, territory, customer base and demand forecast.

04

Technical enquiries

Provide the hazard, equipment, location conditions and required documents.

Safety first

Use only where the exact model is rated and approved

Portable extinguishers are intended for incipient-stage fires and trained use. Agent discharge can create visibility, exposure, pressure and ventilation concerns. Follow the product label, safety data sheet and workplace emergency plan.

  • Raise the alarm and contact the fire and emergency services.
  • Keep a clear escape route and evacuate if conditions worsen.
  • De-energise equipment only when it is safe and procedures permit it.
  • Do not infer electrical suitability from “clean agent” terminology alone.
  • Arrange inspection, refilling and maintenance through competent personnel.
Pan-India enquiry coverage

Manufacturer, supplier and dealer enquiries across India

Vintex accepts 1 kg clean agent extinguisher enquiries from all 28 states and 8 union territories. The cities below are representative commercial and project locations; confirm suitability, availability, documents, commercial approval, delivery and support for the exact destination.

Andhra Pradesh

Visakhapatnam, Vijayawada, Guntur, Tirupati, Nellore, Kurnool, Rajahmundry and Kakinada

Arunachal Pradesh

Itanagar, Naharlagun, Pasighat, Tawang, Ziro and Bomdila

Assam

Guwahati, Dibrugarh, Silchar, Jorhat, Tezpur, Tinsukia and Nagaon

Bihar

Patna, Gaya, Muzaffarpur, Bhagalpur, Darbhanga, Purnia and Bihar Sharif

Chhattisgarh

Raipur, Bhilai, Durg, Bilaspur, Korba, Raigarh and Jagdalpur

Goa

Panaji, Margao, Vasco da Gama, Mapusa and Ponda

Gujarat

Ahmedabad, Surat, Vadodara, Rajkot, Gandhinagar, Bharuch, Vapi, Jamnagar and Bhavnagar

Haryana

Gurugram, Faridabad, Panipat, Sonipat, Ambala, Karnal, Hisar and Manesar

Himachal Pradesh

Shimla, Dharamshala, Solan, Baddi, Mandi, Kullu and Una

Jharkhand

Ranchi, Jamshedpur, Dhanbad, Bokaro, Deoghar and Hazaribagh

Karnataka

Bengaluru, Mysuru, Mangaluru, Hubballi-Dharwad, Belagavi, Ballari, Tumakuru and Davanagere

Kerala

Thiruvananthapuram, Kochi, Kozhikode, Thrissur, Kollam, Kannur, Alappuzha and Palakkad

Madhya Pradesh

Indore, Bhopal, Jabalpur, Gwalior, Ujjain, Sagar, Satna and Dewas

Manipur

Imphal, Thoubal, Bishnupur and Churachandpur

Meghalaya

Shillong, Tura, Jowai and Nongpoh

Mizoram

Aizawl, Lunglei, Champhai and Kolasib

Nagaland

Dimapur, Kohima, Mokokchung and Wokha

Odisha

Bhubaneswar, Cuttack, Rourkela, Sambalpur, Berhampur, Puri, Balasore and Jharsuguda

Punjab

Ludhiana, Amritsar, Jalandhar, Mohali, Patiala, Bathinda and Pathankot

Rajasthan

Jaipur, Jodhpur, Udaipur, Kota, Ajmer, Bikaner, Alwar, Neemrana and Bhilwara

Sikkim

Gangtok, Namchi, Gyalshing, Mangan and Rangpo

Tamil Nadu

Chennai, Coimbatore, Madurai, Tiruchirappalli, Salem, Tiruppur, Hosur, Vellore and Thoothukudi

Telangana

Hyderabad, Secunderabad, Warangal, Karimnagar, Nizamabad, Khammam and Sangareddy

Tripura

Agartala, Udaipur, Dharmanagar and Kailasahar

Uttar Pradesh

Lucknow, Noida, Greater Noida, Ghaziabad, Kanpur, Agra, Varanasi, Prayagraj, Meerut, Gorakhpur and Bareilly

Uttarakhand

Dehradun, Haridwar, Roorkee, Haldwani, Rudrapur and Rishikesh

West Bengal

Kolkata, Howrah, Durgapur, Asansol, Siliguri, Haldia and Kharagpur

Andaman and Nicobar Islands

Port Blair and other project locations across the islands, subject to logistics

Chandigarh

Chandigarh, Mohali, Panchkula and the adjoining Tricity region

Dadra and Nagar Haveli and Daman and Diu

Silvassa, Daman and Diu

Delhi

New Delhi, Central Delhi, North Delhi, South Delhi, East Delhi, West Delhi and NCR project locations

Jammu and Kashmir

Srinagar, Jammu, Anantnag, Baramulla, Kathua and Udhampur

Ladakh

Leh and Kargil, subject to project conditions and logistics

Lakshadweep

Kavaratti and other project locations, subject to logistics

Puducherry

Puducherry, Karaikal, Mahe and Yanam

Coverage note: City and state names indicate enquiry relevance. They do not represent a physical Vintex branch, authorised dealer, stocked inventory or guaranteed same-day service in every location.

Frequently asked questions

1 kg clean agent extinguisher FAQs

What is the Vintex VFP CA 1 extinguisher used for?

The visible product data lists a 1 kg HFC 236 clean agent extinguisher with an 8B rating. Use it only for hazards covered by the exact current label, approval and datasheet.

Can this 1 kg extinguisher be used on energized electrical equipment?

Only if the exact supplied model is tested, rated and approved for that use. Verify the current label, electrical-conductivity information, agent data and manufacturer instructions.

Does an HFC 236 clean agent extinguisher leave residue?

Clean agents are generally selected where solid powder or foam cleanup is undesirable, but buyers should confirm the discharge characteristics and compatibility in the exact agent datasheet and safety data sheet.

Is a 1 kg extinguisher suitable for every server room or vehicle?

No. Capacity, rating and placement must follow a competent risk assessment, the actual fire load, equipment, enclosure, ventilation and applicable requirements.

Which documents should a buyer request?

Request the current datasheet, exact agent name, fire rating, applicable BIS licence and marking, safety data sheet, test documents, operating instructions and maintenance requirements.

Does Vintex accept manufacturer, supplier and dealer enquiries across India?

Vintex accepts project, bulk-supply, supplier and prospective dealer enquiries from Mumbai, Maharashtra and all Indian states and union territories, subject to model, quantity, documentation, commercial approval and delivery confirmation.

Quick Enquiry
Contact Us