1 kg capacity
Compact portable format; verify that the listed rating covers the assessed hazard.
CORPORATE OFFICE: 1701, ORIANA BUSINESS PARK, ROAD NO. 22, WAGLE ESTATE, THANE(W), MAHARASHTRA, INDIA – 400604.
| Model | VFP CA 1 |
| Capacity | 1 Kgs. |
| IS No. | IS 15683:2018 — verify the current BIS licence and marking for the exact supplied model |
| Fire Rating | 8B |
| Operating Temperature | -20° C TO +55° C |
| Min. Jet Length (in mtrs) | 2 Mtrs. |
| Discharge Percentage Min. | 95% |
| Discharge Time Min. | 8 Seconds |
| Charge Pressure | 15 Kgf / cm² |
| Test Pressure | 250 Kgf / cm² |
| Operating Valves | Squeeze Grip Type |
| Extinguisher Media | HFC 236 |
| Expellant | Dry Nitrogen |
| Anti Corrosive Treatment | Phosphating (7 Tanks) |
| Painting | Epoxy Polyester Powder Coating |
| Tare Weight ( Approximate) | 1.2 kg |
| Full Weight ( Approximate) | 2.2 kg |
The Vintex VFP CA 1 is listed as a 1 kg portable clean agent fire extinguisher using HFC 236 medium with an 8B fire rating. It should only be selected for hazards covered by the exact current label, datasheet and approvals. Additional electrical or fire-class suitability must be verified rather than assumed.
The visible product data lists a 1 kg capacity, squeeze-grip operation, dry-nitrogen expellant, approximately 8-second discharge time and HFC 236 extinguishing medium. Its compact format can support selected portable-fire requirements where the rating is appropriate.
A clean agent category name does not establish suitability for every electronic, vehicle or server-room hazard. Confirm the actual fire load, enclosure, ventilation, agent compatibility, operating conditions and local approval requirements.
Compact portable format; verify that the listed rating covers the assessed hazard.
Use this model reference when requesting current documents and quotation details.
Request the exact agent datasheet, safety data sheet and regulatory information.
Do not extend this rating to other fire classes without current test and approval evidence.
BIS lists IS 15683:2018, Portable Fire Extinguishers — Performance and Construction — Specification. If an ISI-marked unit is required, verify the current BIS licence, scope, model marking, rating and test documents for VFP CA 1. Also request the HFC 236 safety data sheet and applicable environmental or regulatory information.
Vintex accepts project and bulk enquiries from facilities, contractors, consultants, system integrators and procurement teams. Share the model, exact agent and rating requirement, quantity, destination and approval conditions.
Supplier and prospective dealer enquiries are reviewed against territory, demand, product mix, commercial terms and service capability. Enquiry coverage does not mean an authorised dealer or stocked inventory already exists in every city.
Request current technical data, agent information, certification and project quantities.
Submit destination, quantity, specifications and delivery requirement for supply support.
Share your company profile, territory, customer base and demand forecast.
Provide the hazard, equipment, location conditions and required documents.
Portable extinguishers are intended for incipient-stage fires and trained use. Agent discharge can create visibility, exposure, pressure and ventilation concerns. Follow the product label, safety data sheet and workplace emergency plan.
Vintex accepts 1 kg clean agent extinguisher enquiries from all 28 states and 8 union territories. The cities below are representative commercial and project locations; confirm suitability, availability, documents, commercial approval, delivery and support for the exact destination.
Visakhapatnam, Vijayawada, Guntur, Tirupati, Nellore, Kurnool, Rajahmundry and Kakinada
Itanagar, Naharlagun, Pasighat, Tawang, Ziro and Bomdila
Guwahati, Dibrugarh, Silchar, Jorhat, Tezpur, Tinsukia and Nagaon
Patna, Gaya, Muzaffarpur, Bhagalpur, Darbhanga, Purnia and Bihar Sharif
Raipur, Bhilai, Durg, Bilaspur, Korba, Raigarh and Jagdalpur
Panaji, Margao, Vasco da Gama, Mapusa and Ponda
Ahmedabad, Surat, Vadodara, Rajkot, Gandhinagar, Bharuch, Vapi, Jamnagar and Bhavnagar
Gurugram, Faridabad, Panipat, Sonipat, Ambala, Karnal, Hisar and Manesar
Shimla, Dharamshala, Solan, Baddi, Mandi, Kullu and Una
Ranchi, Jamshedpur, Dhanbad, Bokaro, Deoghar and Hazaribagh
Bengaluru, Mysuru, Mangaluru, Hubballi-Dharwad, Belagavi, Ballari, Tumakuru and Davanagere
Thiruvananthapuram, Kochi, Kozhikode, Thrissur, Kollam, Kannur, Alappuzha and Palakkad
Indore, Bhopal, Jabalpur, Gwalior, Ujjain, Sagar, Satna and Dewas
Mumbai, Navi Mumbai, Thane, Pune, Nagpur, Nashik, Chhatrapati Sambhajinagar, Kolhapur, Solapur, Palghar and Raigad
Imphal, Thoubal, Bishnupur and Churachandpur
Shillong, Tura, Jowai and Nongpoh
Aizawl, Lunglei, Champhai and Kolasib
Dimapur, Kohima, Mokokchung and Wokha
Bhubaneswar, Cuttack, Rourkela, Sambalpur, Berhampur, Puri, Balasore and Jharsuguda
Ludhiana, Amritsar, Jalandhar, Mohali, Patiala, Bathinda and Pathankot
Jaipur, Jodhpur, Udaipur, Kota, Ajmer, Bikaner, Alwar, Neemrana and Bhilwara
Gangtok, Namchi, Gyalshing, Mangan and Rangpo
Chennai, Coimbatore, Madurai, Tiruchirappalli, Salem, Tiruppur, Hosur, Vellore and Thoothukudi
Hyderabad, Secunderabad, Warangal, Karimnagar, Nizamabad, Khammam and Sangareddy
Agartala, Udaipur, Dharmanagar and Kailasahar
Lucknow, Noida, Greater Noida, Ghaziabad, Kanpur, Agra, Varanasi, Prayagraj, Meerut, Gorakhpur and Bareilly
Dehradun, Haridwar, Roorkee, Haldwani, Rudrapur and Rishikesh
Kolkata, Howrah, Durgapur, Asansol, Siliguri, Haldia and Kharagpur
Port Blair and other project locations across the islands, subject to logistics
Chandigarh, Mohali, Panchkula and the adjoining Tricity region
Silvassa, Daman and Diu
New Delhi, Central Delhi, North Delhi, South Delhi, East Delhi, West Delhi and NCR project locations
Srinagar, Jammu, Anantnag, Baramulla, Kathua and Udhampur
Leh and Kargil, subject to project conditions and logistics
Kavaratti and other project locations, subject to logistics
Puducherry, Karaikal, Mahe and Yanam
Coverage note: City and state names indicate enquiry relevance. They do not represent a physical Vintex branch, authorised dealer, stocked inventory or guaranteed same-day service in every location.
The visible product data lists a 1 kg HFC 236 clean agent extinguisher with an 8B rating. Use it only for hazards covered by the exact current label, approval and datasheet.
Only if the exact supplied model is tested, rated and approved for that use. Verify the current label, electrical-conductivity information, agent data and manufacturer instructions.
Clean agents are generally selected where solid powder or foam cleanup is undesirable, but buyers should confirm the discharge characteristics and compatibility in the exact agent datasheet and safety data sheet.
No. Capacity, rating and placement must follow a competent risk assessment, the actual fire load, equipment, enclosure, ventilation and applicable requirements.
Request the current datasheet, exact agent name, fire rating, applicable BIS licence and marking, safety data sheet, test documents, operating instructions and maintenance requirements.
Vintex accepts project, bulk-supply, supplier and prospective dealer enquiries from Mumbai, Maharashtra and all Indian states and union territories, subject to model, quantity, documentation, commercial approval and delivery confirmation.